Availability: | |
---|---|
R32 Refrigerant
Solareast’s BLN series heat pumps utilize eco-friendly R32 refrigerant, a key component in reducing environmental impact. R32 has a significantly lower global warming potential compared to other commonly used refrigerants, which helps in minimizing greenhouse gas emissions. This environmentally responsible refrigerant choice aligns with Solareast’s ongoing commitment to sustainability and energy efficiency. By adopting R32, these heat pumps not only provide effective home heating but also contribute to reducing the carbon footprint, making them a cleaner and greener option for environmentally-conscious homeowners seeking energy-efficient solutions.
Energy Class A++
With an A++ energy rating, Solareast's BLN series heat pumps reduce energy usage by up to 59%, delivering exceptional efficiency. Designed for optimal energy utilization, these units help lower costs while maintaining eco-friendly operation and sustainable heating solutions.
Stable operation at -25°C
Solareast’s BLN heat pumps maintain stable operation down to -25°C, ensuring reliable heating even in severe winter conditions. Built for consistent performance, they provide comfort in any climate, supporting homeowners with dependable heating all year.
Quality Assurance
Solareast adheres to rigorous quality assurance protocols throughout the production cycle. From research and development to final assembly, each heat pump undergoes thorough testing by skilled technicians using advanced equipment, ensuring optimal performance, durability, and reliability in real-world conditions.
Solareast Overseas Showroom
Solareast has set up a 1200-square-meter overseas showroom to display a wide range of products such as heat pumps, water tanks and solar energy. With the arrival of the Canton Fair, the showroom has attracted many international customers, allowing them to experience Solareast's innovative and environmentally friendly technologies, thus strengthening the company's global presence and commitment to sustainable development.
R32 Refrigerant
Solareast’s BLN series heat pumps utilize eco-friendly R32 refrigerant, a key component in reducing environmental impact. R32 has a significantly lower global warming potential compared to other commonly used refrigerants, which helps in minimizing greenhouse gas emissions. This environmentally responsible refrigerant choice aligns with Solareast’s ongoing commitment to sustainability and energy efficiency. By adopting R32, these heat pumps not only provide effective home heating but also contribute to reducing the carbon footprint, making them a cleaner and greener option for environmentally-conscious homeowners seeking energy-efficient solutions.
Energy Class A++
With an A++ energy rating, Solareast's BLN series heat pumps reduce energy usage by up to 59%, delivering exceptional efficiency. Designed for optimal energy utilization, these units help lower costs while maintaining eco-friendly operation and sustainable heating solutions.
Stable operation at -25°C
Solareast’s BLN heat pumps maintain stable operation down to -25°C, ensuring reliable heating even in severe winter conditions. Built for consistent performance, they provide comfort in any climate, supporting homeowners with dependable heating all year.
Quality Assurance
Solareast adheres to rigorous quality assurance protocols throughout the production cycle. From research and development to final assembly, each heat pump undergoes thorough testing by skilled technicians using advanced equipment, ensuring optimal performance, durability, and reliability in real-world conditions.
Solareast Overseas Showroom
Solareast has set up a 1200-square-meter overseas showroom to display a wide range of products such as heat pumps, water tanks and solar energy. With the arrival of the Canton Fair, the showroom has attracted many international customers, allowing them to experience Solareast's innovative and environmentally friendly technologies, thus strengthening the company's global presence and commitment to sustainable development.
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |