Availability: | |
---|---|
Solareast Heat Pump Ltd. offers a reliable and efficient R32 residential heating and cooling heat pump system
Water temperature at the outlet up to 60°C
One of the highlights of the BLN series of domestic heat pumps is their ability to deliver water at temperatures of up to 60°C. These heat pumps provide excellent high temperature hot water supply for a warm and comfortable bathing or showering experience.Solareast's BLN series of heat pumps can quickly and efficiently heat water up to temperatures of up to 60°C to meet the growing demand for hot water in the home. Because of this feature, the BLN series heat pumps provide users with reliable and efficient heating performance, making them ideal for cold climates or applications where high temperature hot water is in demand. During the cold winter months, users can easily enjoy the warmth of hot water without having to wait too long.
Ultra Quiet
Solareast's BLN range of domestic heat pumps utilizes advanced technology and quality components to effectively reduce the noise levels generated during operation, ensuring quiet, smooth operation. With noise levels as low as 45 decibels, this range of heat pumps is one of the quietest on the market today. This feature makes it ideal for families seeking a quieter home environment, free from the distractions of noisy heating systems. In addition, the ultra-quiet operation of the BLN Series heat pumps allows users to optimize energy consumption without compromising comfort. With the BLN range of domestic heat pumps, Solareast offers users a heating solution that is not only efficient and reliable, but also delivers an ultra-quiet experience, making it the perfect choice for families who value quiet living. Users can enjoy comfortable warmth without worrying about the noise generated by the heat pump operation affecting their quality of life.
Energy class: A++,high efficiency and more energy-saving
The Solareast R32 BLN series' ultra-low temperature full DC inverter speed control offers significant energy savings of up to 59%. Compared with other inverter units, Solareast heat pumps can achieve 1Hz stepless inverter free operation with an A++ energy efficiency rating. Under the same conditions of use, using a Solareast R32 BLN series heat pump can save more energy than using other inverter units, while providing more efficient heating or cooling.
The BLN series heat pumps not only provide excellent heating performance, but also place a high priority on energy efficiency. Through the use of advanced technology and components, BLN Series heat pumps maximize energy efficiency and minimize energy waste.BLN Series heat pumps are highly efficient, providing effective heating while reducing energy consumption, resulting in significant cost savings for homeowners. In addition, the A++ energy rating demonstrates Solareast's commitment to sustainability by providing environmentally friendly heating solutions.The BLN series of home heat pumps is the perfect choice for those seeking comfort and energy efficiency, as well as reliable, efficient home heating.
Eco-friendly R32 refrigerant
The Solareast R32 BLN series utilizes R32 refrigerant, which has a global warming potential (GWP) of only 675, which is 70% less than R410A. As a green heating solution, the R32 BLN series offers excellent energy efficiency. At the same time, R32 refrigerant has a lower environmental impact and is environmentally friendly.
R32 has a lower global warming potential than other commonly used refrigerants, which means it has a lower impact on the environment, making it a more sustainable choice.The BLN series of heat pumps uses R32 refrigerant, which helps to reduce greenhouse gas emissions and minimize the impact on the environment. This eco-friendly feature is in line with Solareast's commitment to sustainability and provides homeowners with a greener home heating solution. Additionally, the use of R32 refrigerant in the BLN Series heat pumps ensures optimal performance and energy efficiency, allowing homeowners to enjoy efficient, reliable heating while reducing their carbon footprint. With the BLN series of home heat pumps, Solareast offers an environmentally responsible heating solution that saves energy and saves the environment.
Stable operation at -25°C
The Solareast BLN range of domestic heat pumps has a minimum operating temperature as low as -25°C, an outstanding feature that ensures stable operation in extreme cold conditions. Even in the harshest winter conditions, modern technology and components allow the BLN series heat pumps to keep running efficiently, providing warmth and comfort to the home.The Solareast BLN series heat pumps can operate in temperatures as low as -25°C, meaning that they can provide reliable heating regardless of the outdoor temperature. This feature demonstrates Solareast's commitment to meeting the diverse heating needs of its customers, ensuring that they can enjoy comfort even in inclement weather.
Renewable Energy
A heat pump is an environmentally friendly system that utilizes nature's renewable energy sources. Renewable energy comes from self-renewable sources such as solar, wind and water, which regenerate faster than they are consumed. Air supply is one such renewable source of energy, and Solareast heat pumps utilize air source technology for efficient heating and cooling. The utilization of air source is in line with the principles of protecting the environment and promoting the reuse of resources. By using air source technology, Solareast heat pumps utilize renewable energy from the air supply to provide homeowners with an environmentally friendly solution to their heating and cooling needs. Solareast heat pumps offer higher energy efficiency and lower environmental impact than traditional heating and cooling systems. By utilizing renewable energy and prioritizing resource reuse, heat pumps from companies like Solareast contribute to a sustainable and greener future.
Solareast Heat Pump Ltd. offers a reliable and efficient R32 residential heating and cooling heat pump system
Water temperature at the outlet up to 60°C
One of the highlights of the BLN series of domestic heat pumps is their ability to deliver water at temperatures of up to 60°C. These heat pumps provide excellent high temperature hot water supply for a warm and comfortable bathing or showering experience.Solareast's BLN series of heat pumps can quickly and efficiently heat water up to temperatures of up to 60°C to meet the growing demand for hot water in the home. Because of this feature, the BLN series heat pumps provide users with reliable and efficient heating performance, making them ideal for cold climates or applications where high temperature hot water is in demand. During the cold winter months, users can easily enjoy the warmth of hot water without having to wait too long.
Ultra Quiet
Solareast's BLN range of domestic heat pumps utilizes advanced technology and quality components to effectively reduce the noise levels generated during operation, ensuring quiet, smooth operation. With noise levels as low as 45 decibels, this range of heat pumps is one of the quietest on the market today. This feature makes it ideal for families seeking a quieter home environment, free from the distractions of noisy heating systems. In addition, the ultra-quiet operation of the BLN Series heat pumps allows users to optimize energy consumption without compromising comfort. With the BLN range of domestic heat pumps, Solareast offers users a heating solution that is not only efficient and reliable, but also delivers an ultra-quiet experience, making it the perfect choice for families who value quiet living. Users can enjoy comfortable warmth without worrying about the noise generated by the heat pump operation affecting their quality of life.
Energy class: A++,high efficiency and more energy-saving
The Solareast R32 BLN series' ultra-low temperature full DC inverter speed control offers significant energy savings of up to 59%. Compared with other inverter units, Solareast heat pumps can achieve 1Hz stepless inverter free operation with an A++ energy efficiency rating. Under the same conditions of use, using a Solareast R32 BLN series heat pump can save more energy than using other inverter units, while providing more efficient heating or cooling.
The BLN series heat pumps not only provide excellent heating performance, but also place a high priority on energy efficiency. Through the use of advanced technology and components, BLN Series heat pumps maximize energy efficiency and minimize energy waste.BLN Series heat pumps are highly efficient, providing effective heating while reducing energy consumption, resulting in significant cost savings for homeowners. In addition, the A++ energy rating demonstrates Solareast's commitment to sustainability by providing environmentally friendly heating solutions.The BLN series of home heat pumps is the perfect choice for those seeking comfort and energy efficiency, as well as reliable, efficient home heating.
Eco-friendly R32 refrigerant
The Solareast R32 BLN series utilizes R32 refrigerant, which has a global warming potential (GWP) of only 675, which is 70% less than R410A. As a green heating solution, the R32 BLN series offers excellent energy efficiency. At the same time, R32 refrigerant has a lower environmental impact and is environmentally friendly.
R32 has a lower global warming potential than other commonly used refrigerants, which means it has a lower impact on the environment, making it a more sustainable choice.The BLN series of heat pumps uses R32 refrigerant, which helps to reduce greenhouse gas emissions and minimize the impact on the environment. This eco-friendly feature is in line with Solareast's commitment to sustainability and provides homeowners with a greener home heating solution. Additionally, the use of R32 refrigerant in the BLN Series heat pumps ensures optimal performance and energy efficiency, allowing homeowners to enjoy efficient, reliable heating while reducing their carbon footprint. With the BLN series of home heat pumps, Solareast offers an environmentally responsible heating solution that saves energy and saves the environment.
Stable operation at -25°C
The Solareast BLN range of domestic heat pumps has a minimum operating temperature as low as -25°C, an outstanding feature that ensures stable operation in extreme cold conditions. Even in the harshest winter conditions, modern technology and components allow the BLN series heat pumps to keep running efficiently, providing warmth and comfort to the home.The Solareast BLN series heat pumps can operate in temperatures as low as -25°C, meaning that they can provide reliable heating regardless of the outdoor temperature. This feature demonstrates Solareast's commitment to meeting the diverse heating needs of its customers, ensuring that they can enjoy comfort even in inclement weather.
Renewable Energy
A heat pump is an environmentally friendly system that utilizes nature's renewable energy sources. Renewable energy comes from self-renewable sources such as solar, wind and water, which regenerate faster than they are consumed. Air supply is one such renewable source of energy, and Solareast heat pumps utilize air source technology for efficient heating and cooling. The utilization of air source is in line with the principles of protecting the environment and promoting the reuse of resources. By using air source technology, Solareast heat pumps utilize renewable energy from the air supply to provide homeowners with an environmentally friendly solution to their heating and cooling needs. Solareast heat pumps offer higher energy efficiency and lower environmental impact than traditional heating and cooling systems. By utilizing renewable energy and prioritizing resource reuse, heat pumps from companies like Solareast contribute to a sustainable and greener future.
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |