Availability: | |
---|---|
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=3IqGZ-tr6vE
Ultra Quiet Operating Mode
The Solareast air-to-water heat pump features an ultra-quiet operating mode, designed to reduce noise levels during periods when quiet operation is essential, such as nighttime. By adjusting the compressor and fan power, the system can operate at half the noise level of standard models, creating a peaceful environment without sacrificing performance. This thoughtful design enhances user comfort by maintaining a quiet atmosphere, while also optimizing energy efficiency. The quiet operation makes the air-to-water heat pump an excellent choice for residential and commercial environments where noise reduction is a priority.
Exclusive Design To Work In The Most Extreme Condition
The Solareast air-to-water heat pump is engineered to perform efficiently across a wide range of outdoor temperatures, from as low as -25°C to as high as 35°C. This versatile design ensures reliable operation, whether facing freezing winters or hot summer days. The heat pump maintains optimal performance regardless of the weather conditions, delivering consistent heating and hot water year-round. This robust ability to function in extreme climates makes it the perfect solution for diverse geographical areas, providing dependable comfort and energy efficiency in any environment.
Efficient IoT Solution
The Solareast IoT platform revolutionizes customer management by enabling dealers to remotely monitor and optimize the performance of air-to-water heat pumps. This efficient solution reduces labor costs and enhances customer service by offering real-time performance monitoring and predictive maintenance capabilities. The platform syncs data seamlessly, allowing dealers to integrate their systems with manufacturers' systems for improved communication and workflow efficiency. The IoT solution enables proactive management, ensuring the heat pumps operate at peak performance while simplifying processes for both dealers and customers, optimizing the overall experience.
Proven Quality
Quality Assurance
At Solareast, quality is paramount. The company maintains a rigorous quality management system that spans every stage of production, from research and development to manufacturing. Each heat pump undergoes comprehensive performance testing to verify its reliability, longevity, and efficiency. By adhering to international quality standards and utilizing advanced manufacturing processes, Solareast ensures that every product performs optimally throughout its lifecycle. This dedication to quality guarantees that customers receive durable, high-performing products that exceed industry expectations, providing exceptional value and confidence for years to come.
Solareast Overseas Product Showroom
In order to strengthen its global expansion strategy, Solareast opened a 1,200 square metre showroom to display a wide range of products including heat pumps, water tanks, solar solutions and more. The showroom was set up to provide a platform to showcase the company's innovative products and attracted many customers from different countries, especially during the Canton Fair. This dedicated exhibition space provided customers with the opportunity to experience Solareast's environmentally friendly technology and high-performance products first-hand, further consolidating Solareast's presence in the global market and building closer ties with international partners.
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=3IqGZ-tr6vE
Ultra Quiet Operating Mode
The Solareast air-to-water heat pump features an ultra-quiet operating mode, designed to reduce noise levels during periods when quiet operation is essential, such as nighttime. By adjusting the compressor and fan power, the system can operate at half the noise level of standard models, creating a peaceful environment without sacrificing performance. This thoughtful design enhances user comfort by maintaining a quiet atmosphere, while also optimizing energy efficiency. The quiet operation makes the air-to-water heat pump an excellent choice for residential and commercial environments where noise reduction is a priority.
Exclusive Design To Work In The Most Extreme Condition
The Solareast air-to-water heat pump is engineered to perform efficiently across a wide range of outdoor temperatures, from as low as -25°C to as high as 35°C. This versatile design ensures reliable operation, whether facing freezing winters or hot summer days. The heat pump maintains optimal performance regardless of the weather conditions, delivering consistent heating and hot water year-round. This robust ability to function in extreme climates makes it the perfect solution for diverse geographical areas, providing dependable comfort and energy efficiency in any environment.
Efficient IoT Solution
The Solareast IoT platform revolutionizes customer management by enabling dealers to remotely monitor and optimize the performance of air-to-water heat pumps. This efficient solution reduces labor costs and enhances customer service by offering real-time performance monitoring and predictive maintenance capabilities. The platform syncs data seamlessly, allowing dealers to integrate their systems with manufacturers' systems for improved communication and workflow efficiency. The IoT solution enables proactive management, ensuring the heat pumps operate at peak performance while simplifying processes for both dealers and customers, optimizing the overall experience.
Proven Quality
Quality Assurance
At Solareast, quality is paramount. The company maintains a rigorous quality management system that spans every stage of production, from research and development to manufacturing. Each heat pump undergoes comprehensive performance testing to verify its reliability, longevity, and efficiency. By adhering to international quality standards and utilizing advanced manufacturing processes, Solareast ensures that every product performs optimally throughout its lifecycle. This dedication to quality guarantees that customers receive durable, high-performing products that exceed industry expectations, providing exceptional value and confidence for years to come.
Solareast Overseas Product Showroom
In order to strengthen its global expansion strategy, Solareast opened a 1,200 square metre showroom to display a wide range of products including heat pumps, water tanks, solar solutions and more. The showroom was set up to provide a platform to showcase the company's innovative products and attracted many customers from different countries, especially during the Canton Fair. This dedicated exhibition space provided customers with the opportunity to experience Solareast's environmentally friendly technology and high-performance products first-hand, further consolidating Solareast's presence in the global market and building closer ties with international partners.
Hydraulic Module Without Water Tank
Model | HU-3K/6LA1 | HU-9K/6LA3 | |
Power Supply | 220-240/1/50 | 380-415/1/50 | |
Auxiliary heater power | kW | 3 | 9 |
Power Input Max. | kW | 3.5 | 3.5 |
Current Input Max. | A | 15.6 | 16.2 |
Electrical Shockproof | / | I | |
IP Class | / | IPX1 | |
Water Piping Connections | In | G1 | |
Water Pressure Drop | kPa | 10 | |
Water Pressure Min/Max | Mpa | 0.1/0.3 | |
Sound Pressure level | dB(A) | 35 | |
Unit Dimensions (W/H/D) | mm | 420×670×260 | |
Shipping Dimensions (W/H/D) | mm | 480×720×310 | |
Net Weight | kg | 29 | |
Gross Weight | kg | 33 |
Hydraulic Module With Water Tank
Model | HUST-200LA1 | HUST-200LA3 | HUST-250LA1 | HUST-250LA3 | ||
Power Supply | 220-240/1/50 | 380-415/1/50 | 220-240/1/50 | 380-415/3/50 | ||
Auxiliary heater power | kW | 3 | 9 | 3 | 9 | |
Power Input Max. | kW | 3.5 | 9.5 | 3.5 | 9.5 | |
Current Input Max. | A | 15.6 | 16.2 | 15.6 | 16.2 | |
Hot Water Tank Volume | L | 200 | 200 | 250 | 250 | |
Electrical Shockproof | / | I | ||||
IP Class | / | IPX1 | ||||
Hot Water Piping Connections | In | G3/4 | ||||
Heating Water Piping Connections | In | G1 | ||||
Water Pressure Drop | kPa | 10 | ||||
Water Pressure Min/Max | Mpa | 0.1/0.3 | ||||
Hot Water Tank Pressure Max. | Mpa | 0.8 | ||||
Sound Pressure level | dB(A) | 35 | ||||
Exchange Coil Shape | / | corrugation | ||||
Heat Exchange Coil Dimensions | mm | ∅28*25000 | ||||
Net Weight | kg | 95 | 120 | |||
Gross Weight | kg | 105 | 130 |
R290 Air Source Monoblock Heat Pump
Model | BLN ~ 006TC1 | BLN ~ 012TC1 | BLN ~ 018TC1 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.30 ~ 15.20 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 4.02 ~ 16.38 | 6.86 ~ 30.25 | |
COP | W/W | 4.31 ~ 5.66 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 4.25 ~ 14.55 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 6.71 ~ 18.80 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | |
Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 1.38 ~ 5.70 | 3.65 ~ 11.04 | 4.55 ~ 17.20 |
Input Power | kW | 0.67 ~ 2.44 | 1.12~3.97 | 1.85 ~ 7.31 | |
Input Current | A | 3.06 ~ 10.27 | 5.18~17.44 | 8.47 ~ 32.1 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||
Rated Input Power | kW | 3.5 | 5.40 | 7.5 | |
Rated Input Current | A | 15.0 | 25.0 | 35.0 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.4 / 3 | ||
Rated water flow | m³/h | 1.00 | 2.06 | ||
Fan quantity | / | 1 | 2 | ||
Fan motor type | / | DC inverter | |||
Compressor | / | DC inverter | |||
Circulating pump | / | Inverter type / Built ~ in | |||
IP Class | / | IPX4 | |||
Sound pressure at 1m distance | dB(A) | 46 | 53 | 56 | |
Max. outlet water Temp. | °C | 75 | |||
Water Piping Connections | inch | G1 | G1 ~ 1 / 4 | ||
Water Pressure Drop | kPa | 20 | 55 | ||
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||
Operating temperature range (Cooing mode) | °C | 16~45 | |||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 195 | |
Packed Weight | kg | 122 | 146 | 208 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.
Hydraulic Module Without Water Tank
Model | HU-3K/6LA1 | HU-9K/6LA3 | |
Power Supply | 220-240/1/50 | 380-415/1/50 | |
Auxiliary heater power | kW | 3 | 9 |
Power Input Max. | kW | 3.5 | 3.5 |
Current Input Max. | A | 15.6 | 16.2 |
Electrical Shockproof | / | I | |
IP Class | / | IPX1 | |
Water Piping Connections | In | G1 | |
Water Pressure Drop | kPa | 10 | |
Water Pressure Min/Max | Mpa | 0.1/0.3 | |
Sound Pressure level | dB(A) | 35 | |
Unit Dimensions (W/H/D) | mm | 420×670×260 | |
Shipping Dimensions (W/H/D) | mm | 480×720×310 | |
Net Weight | kg | 29 | |
Gross Weight | kg | 33 |
Hydraulic Module With Water Tank
Model | HUST-200LA1 | HUST-200LA3 | HUST-250LA1 | HUST-250LA3 | ||
Power Supply | 220-240/1/50 | 380-415/1/50 | 220-240/1/50 | 380-415/3/50 | ||
Auxiliary heater power | kW | 3 | 9 | 3 | 9 | |
Power Input Max. | kW | 3.5 | 9.5 | 3.5 | 9.5 | |
Current Input Max. | A | 15.6 | 16.2 | 15.6 | 16.2 | |
Hot Water Tank Volume | L | 200 | 200 | 250 | 250 | |
Electrical Shockproof | / | I | ||||
IP Class | / | IPX1 | ||||
Hot Water Piping Connections | In | G3/4 | ||||
Heating Water Piping Connections | In | G1 | ||||
Water Pressure Drop | kPa | 10 | ||||
Water Pressure Min/Max | Mpa | 0.1/0.3 | ||||
Hot Water Tank Pressure Max. | Mpa | 0.8 | ||||
Sound Pressure level | dB(A) | 35 | ||||
Exchange Coil Shape | / | corrugation | ||||
Heat Exchange Coil Dimensions | mm | ∅28*25000 | ||||
Net Weight | kg | 95 | 120 | |||
Gross Weight | kg | 105 | 130 |
R290 Air Source Monoblock Heat Pump
Model | BLN ~ 006TC1 | BLN ~ 012TC1 | BLN ~ 018TC1 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.30 ~ 15.20 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 4.02 ~ 16.38 | 6.86 ~ 30.25 | |
COP | W/W | 4.31 ~ 5.66 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 4.25 ~ 14.55 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 6.71 ~ 18.80 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | |
Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 1.38 ~ 5.70 | 3.65 ~ 11.04 | 4.55 ~ 17.20 |
Input Power | kW | 0.67 ~ 2.44 | 1.12~3.97 | 1.85 ~ 7.31 | |
Input Current | A | 3.06 ~ 10.27 | 5.18~17.44 | 8.47 ~ 32.1 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||
Rated Input Power | kW | 3.5 | 5.40 | 7.5 | |
Rated Input Current | A | 15.0 | 25.0 | 35.0 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.4 / 3 | ||
Rated water flow | m³/h | 1.00 | 2.06 | ||
Fan quantity | / | 1 | 2 | ||
Fan motor type | / | DC inverter | |||
Compressor | / | DC inverter | |||
Circulating pump | / | Inverter type / Built ~ in | |||
IP Class | / | IPX4 | |||
Sound pressure at 1m distance | dB(A) | 46 | 53 | 56 | |
Max. outlet water Temp. | °C | 75 | |||
Water Piping Connections | inch | G1 | G1 ~ 1 / 4 | ||
Water Pressure Drop | kPa | 20 | 55 | ||
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||
Operating temperature range (Cooing mode) | °C | 16~45 | |||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 195 | |
Packed Weight | kg | 122 | 146 | 208 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.