Availability: | |
---|---|
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=3IqGZ-tr6vE
Highly Efficient Energy Conversion
The Solareast air source heat pump showcases exceptional energy efficiency with an impressive energy conversion ratio. For every 1 kWh of electricity consumed, the system delivers nearly 4 kWh of thermal energy, translating to an efficiency rate of almost 400%. This cutting-edge technology ensures significant energy savings, making it an ideal choice for eco-conscious users. By maximizing energy utilization, the heat pump provides reliable heating and cooling solutions while reducing environmental impact and operational costs, setting a benchmark in sustainable and efficient performance for modern households and commercial spaces.
Low Noise Operation
The Solareast air source heat pump is engineered for quiet performance, generating just 43 decibels of sound at a 1-meter distance. This remarkably low noise level ensures a serene indoor environment, comparable to the peaceful atmosphere of a library or the tranquility of a good night’s sleep. Enjoy the perfect balance of powerful functionality and barely noticeable operation, making it an excellent choice for those seeking comfort without compromise.
Cascade System Up To 16 Heat Pumps
The Solareast air source heat pump cascade system allows the connection of up to 16 units in a series, offering scalable and highly efficient heating solutions for large-scale applications. This system ensures superior performance, flexibility, and energy efficiency by distributing heating loads across multiple units. Perfect for large residential complexes or commercial buildings, the cascade system guarantees consistent temperature control, reduces energy consumption, and provides a reliable, cost-effective heating solution for demanding environments.
Quality Assurance
At Solareast, exceptional quality is at the core of everything we do. The company follows a strict quality management system that governs every phase of production, from research and development to final assembly. Each heat pump undergoes comprehensive testing to verify its operational efficiency, long-term durability, and environmental performance. By adhering to international quality standards and utilizing the latest manufacturing processes, Solareast ensures that every product delivers optimal performance throughout its lifecycle. This unwavering commitment to quality guarantees that customers receive reliable, high-performance heat pumps that exceed industry expectations, offering lasting value and peace of mind.
Solareast Overseas Product Showroom
As part of its global expansion efforts, Solareast has opened a 1,200 square-meter overseas showroom to showcase a wide range of products, including heat pumps, water tanks, solar solutions, and more. This showroom serves as a platform for international customers to experience Solareast's cutting-edge technology and sustainable solutions firsthand. Featuring innovative products that emphasize energy efficiency and performance, the showroom attracts customers from all over the world, especially during key trade events such as the Canton Fair. It strengthens Solareast's global presence and fosters closer relationships with international partners, further enhancing the brand’s recognition in the global market.
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=3IqGZ-tr6vE
Highly Efficient Energy Conversion
The Solareast air source heat pump showcases exceptional energy efficiency with an impressive energy conversion ratio. For every 1 kWh of electricity consumed, the system delivers nearly 4 kWh of thermal energy, translating to an efficiency rate of almost 400%. This cutting-edge technology ensures significant energy savings, making it an ideal choice for eco-conscious users. By maximizing energy utilization, the heat pump provides reliable heating and cooling solutions while reducing environmental impact and operational costs, setting a benchmark in sustainable and efficient performance for modern households and commercial spaces.
Low Noise Operation
The Solareast air source heat pump is engineered for quiet performance, generating just 43 decibels of sound at a 1-meter distance. This remarkably low noise level ensures a serene indoor environment, comparable to the peaceful atmosphere of a library or the tranquility of a good night’s sleep. Enjoy the perfect balance of powerful functionality and barely noticeable operation, making it an excellent choice for those seeking comfort without compromise.
Cascade System Up To 16 Heat Pumps
The Solareast air source heat pump cascade system allows the connection of up to 16 units in a series, offering scalable and highly efficient heating solutions for large-scale applications. This system ensures superior performance, flexibility, and energy efficiency by distributing heating loads across multiple units. Perfect for large residential complexes or commercial buildings, the cascade system guarantees consistent temperature control, reduces energy consumption, and provides a reliable, cost-effective heating solution for demanding environments.
Quality Assurance
At Solareast, exceptional quality is at the core of everything we do. The company follows a strict quality management system that governs every phase of production, from research and development to final assembly. Each heat pump undergoes comprehensive testing to verify its operational efficiency, long-term durability, and environmental performance. By adhering to international quality standards and utilizing the latest manufacturing processes, Solareast ensures that every product delivers optimal performance throughout its lifecycle. This unwavering commitment to quality guarantees that customers receive reliable, high-performance heat pumps that exceed industry expectations, offering lasting value and peace of mind.
Solareast Overseas Product Showroom
As part of its global expansion efforts, Solareast has opened a 1,200 square-meter overseas showroom to showcase a wide range of products, including heat pumps, water tanks, solar solutions, and more. This showroom serves as a platform for international customers to experience Solareast's cutting-edge technology and sustainable solutions firsthand. Featuring innovative products that emphasize energy efficiency and performance, the showroom attracts customers from all over the world, especially during key trade events such as the Canton Fair. It strengthens Solareast's global presence and fosters closer relationships with international partners, further enhancing the brand’s recognition in the global market.
Model | BLN-006TC1 | BLN-008TC1 | BLN-008TC3 | BLN-012TC1 | BLN-012TC3 | BLN-018TC1 | BLN-018TC3 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 80~415/3/50 | 380~415V/3/50 | 380~415V/3/50 | 220~240/1/50 | 380~415V/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.10 -12.10 | 4.10 -12.10 | 4.30 ~ 15.20 | 4.30 ~ 15.20 | 7.24 ~ 21.90 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.61 ~ 2.11 | 0.79 -2.85 | 0.87 ~ 3.73 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 2.80 ~ 9.25 | 3.45-13.04 | 4.02 ~ 16.38 | 1.78 ~ 6.04 | 6.86 ~ 30.25 | 2.82 ~ 9.16 | |
COP | W/W | 4.31 ~ 5.66 | 4.31 ~ 5.66 | 4.24 - 5.57 | 4.07 ~ 5.57 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 2.99~8.16 | 4.05-12.15 | 4.25 ~ 14.55 | 4.25 ~ 14.55 | 6.36 ~ 19.45 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.03~2.92 | 1.38-4.06 | 1.45 ~ 4.28 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 4.57~12.79 | 5.73-17.70 | 6.71 ~ 18.80 | 2.84 ~ 6.78 | 9.84 ~ 30.12 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.79 ~ 3.46 | 2.99 - 3.45 | 2.83 ~ 3.45 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | 2.84 ~ 3.57 | |
Nominal Heating (Max) (A357/24℃,W12/7℃) | Heating Capacity | kW | 1.38 ~ 5.70 | 1.38~5.70 | 3.65-8.59 | 3.65 ~ 11.04 | 3.65 ~ 11.04 | 4.55 ~ 17.20 | 4.55 ~ 17.20 |
Power Input | kW | 0.67 ~ 2.44 | 0.67~2.44 | 1.12-3.31 | 1.12~3.97 | 1.12 ~ 3.97 | 1.85 ~ 7.31 | 1.85 ~ 7.31 | |
Current Input | A | 3.06 ~ 10.27 | 3.06~10.27 | 5.18-14.47 | 5.18~17.44 | 1.97 ~ 6.30 | 8.47 ~ 32.1 | 2.99 ~ 11.26 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||||||
Rated Input Power | kW | 3.5 | 3.5 | 5.40 | 5.85 | 5.85 | 7.5 | 10.5 | |
Rated Input Current | A | 15 | 15 | 25 | 25 | 10 | 35 | 17 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.05 / 3 | R290 / 1.05 /3 | R290 / 1.05 / 3 | R290 / 1.05 / 3 | R290 / 1.4 / 3 | R290 / 1.4 / 3 | |
Rated water flow | m³/h | 1 | 1.4 | 1.4 | 2.06 | 2.06 | 3.1 | 3.1 | |
Fan quantity | / | 1 | |||||||
Fan motor type | / | DC inverter | |||||||
Compressor | / | DC inverter | |||||||
Circulating pump | / | Inverter type / Built ~ in | |||||||
IP Class | / | IPX4 | |||||||
Sound pressure at 1m distance | dB(A) | 46 | 43 | 43 | 53 | 54 | 56 | 56 | |
Max. outlet water Temp. | °C | 75 | |||||||
Water Piping Connections | inch | G1 | G1 | G1 | G1 | G1 | G1 ~ 1 / 4 | G1 ~ 1 / 4 | |
Water Pressure Drop | kPa | 20 | 20 | 20 | 20 | 20 | 50 | 50 | |
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||||||
Operating temperature range (Cooing mode) | °C | 16~45 | |||||||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1287*448*904 | 1287*448*904 | 1287*448*904 | 1187*488*1456 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1317*493*1020 | 1317*493*1020 | 1317*493*1020 | 1217*538*1570 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 134 | 134 | 134 | 195 | 195 | |
Packed Weight | kg | 122 | 146 | 146 | 146 | 146 | 208 | 208 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.
Model | BLN-006TC1 | BLN-008TC1 | BLN-008TC3 | BLN-012TC1 | BLN-012TC3 | BLN-018TC1 | BLN-018TC3 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 80~415/3/50 | 380~415V/3/50 | 380~415V/3/50 | 220~240/1/50 | 380~415V/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.10 -12.10 | 4.10 -12.10 | 4.30 ~ 15.20 | 4.30 ~ 15.20 | 7.24 ~ 21.90 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.61 ~ 2.11 | 0.79 -2.85 | 0.87 ~ 3.73 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 2.80 ~ 9.25 | 3.45-13.04 | 4.02 ~ 16.38 | 1.78 ~ 6.04 | 6.86 ~ 30.25 | 2.82 ~ 9.16 | |
COP | W/W | 4.31 ~ 5.66 | 4.31 ~ 5.66 | 4.24 - 5.57 | 4.07 ~ 5.57 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 2.99~8.16 | 4.05-12.15 | 4.25 ~ 14.55 | 4.25 ~ 14.55 | 6.36 ~ 19.45 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.03~2.92 | 1.38-4.06 | 1.45 ~ 4.28 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 4.57~12.79 | 5.73-17.70 | 6.71 ~ 18.80 | 2.84 ~ 6.78 | 9.84 ~ 30.12 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.79 ~ 3.46 | 2.99 - 3.45 | 2.83 ~ 3.45 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | 2.84 ~ 3.57 | |
Nominal Heating (Max) (A357/24℃,W12/7℃) | Heating Capacity | kW | 1.38 ~ 5.70 | 1.38~5.70 | 3.65-8.59 | 3.65 ~ 11.04 | 3.65 ~ 11.04 | 4.55 ~ 17.20 | 4.55 ~ 17.20 |
Power Input | kW | 0.67 ~ 2.44 | 0.67~2.44 | 1.12-3.31 | 1.12~3.97 | 1.12 ~ 3.97 | 1.85 ~ 7.31 | 1.85 ~ 7.31 | |
Current Input | A | 3.06 ~ 10.27 | 3.06~10.27 | 5.18-14.47 | 5.18~17.44 | 1.97 ~ 6.30 | 8.47 ~ 32.1 | 2.99 ~ 11.26 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||||||
Rated Input Power | kW | 3.5 | 3.5 | 5.40 | 5.85 | 5.85 | 7.5 | 10.5 | |
Rated Input Current | A | 15 | 15 | 25 | 25 | 10 | 35 | 17 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.05 / 3 | R290 / 1.05 /3 | R290 / 1.05 / 3 | R290 / 1.05 / 3 | R290 / 1.4 / 3 | R290 / 1.4 / 3 | |
Rated water flow | m³/h | 1 | 1.4 | 1.4 | 2.06 | 2.06 | 3.1 | 3.1 | |
Fan quantity | / | 1 | |||||||
Fan motor type | / | DC inverter | |||||||
Compressor | / | DC inverter | |||||||
Circulating pump | / | Inverter type / Built ~ in | |||||||
IP Class | / | IPX4 | |||||||
Sound pressure at 1m distance | dB(A) | 46 | 43 | 43 | 53 | 54 | 56 | 56 | |
Max. outlet water Temp. | °C | 75 | |||||||
Water Piping Connections | inch | G1 | G1 | G1 | G1 | G1 | G1 ~ 1 / 4 | G1 ~ 1 / 4 | |
Water Pressure Drop | kPa | 20 | 20 | 20 | 20 | 20 | 50 | 50 | |
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||||||
Operating temperature range (Cooing mode) | °C | 16~45 | |||||||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1287*448*904 | 1287*448*904 | 1287*448*904 | 1187*488*1456 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1317*493*1020 | 1317*493*1020 | 1317*493*1020 | 1217*538*1570 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 134 | 134 | 134 | 195 | 195 | |
Packed Weight | kg | 122 | 146 | 146 | 146 | 146 | 208 | 208 |