Availability: | |
---|---|
Solareast Heat Pump Ltd. offers a reliable and efficient R32 air-to-water heating and cooling system
Consistent Functioning At -25°C
The R32 monoblock heat pump is engineered for extreme reliability, performing efficiently even at temperatures as low as -25°C. With advanced inverter technology and an intelligent defrosting system, it maintains consistent heating performance and hot water production in harsh climates. This durability ensures uninterrupted warmth and comfort throughout the year, showcasing Solareast's technical excellence and commitment to high-quality, climate-adaptive solutions.
Noise Control,No Disturbances
Through rigorous noise-reduction engineering, the R32 monoblock heat pump ensures quiet operation. The combination of full DC technology, stepless compressor speed regulation, and ABS fan blades achieves remarkable sound dampening, making it one of the quietest options available. Solareast prioritizes user comfort, ensuring that the heat pump delivers high performance with minimal disturbance, meeting residential and commercial noise standards for a peaceful environment.
Monoblock heat pump R32 Installation Wiring Diagram
Quality Assurance
Solareast emphasizes strict quality assurance at every stage, from R&D and design to raw material sourcing and production. Our professional team and advanced equipment ensure each heat pump is rigorously tested to achieve outstanding performance and reliability. By continually optimizing our quality control system, we aim to exceed customer expectations with durable, high-performance products, embodying Solareast’s dedication to quality.
Advanced Laboratory
Solareast has invested $3 million in an advanced laboratory capable of simulating extreme temperatures from -30°C to 52°C, certified by TUV and Intertek. This lab enables in-depth testing to verify product durability and performance under various conditions. Recent upgrades, including water drawdown and explosion-proof testing areas, underscore our commitment to safety and high-quality standards, ensuring reliable and long-lasting products.
Solareast Heat Pump Ltd. offers a reliable and efficient R32 air-to-water heating and cooling system
Consistent Functioning At -25°C
The R32 monoblock heat pump is engineered for extreme reliability, performing efficiently even at temperatures as low as -25°C. With advanced inverter technology and an intelligent defrosting system, it maintains consistent heating performance and hot water production in harsh climates. This durability ensures uninterrupted warmth and comfort throughout the year, showcasing Solareast's technical excellence and commitment to high-quality, climate-adaptive solutions.
Noise Control,No Disturbances
Through rigorous noise-reduction engineering, the R32 monoblock heat pump ensures quiet operation. The combination of full DC technology, stepless compressor speed regulation, and ABS fan blades achieves remarkable sound dampening, making it one of the quietest options available. Solareast prioritizes user comfort, ensuring that the heat pump delivers high performance with minimal disturbance, meeting residential and commercial noise standards for a peaceful environment.
Monoblock heat pump R32 Installation Wiring Diagram
Quality Assurance
Solareast emphasizes strict quality assurance at every stage, from R&D and design to raw material sourcing and production. Our professional team and advanced equipment ensure each heat pump is rigorously tested to achieve outstanding performance and reliability. By continually optimizing our quality control system, we aim to exceed customer expectations with durable, high-performance products, embodying Solareast’s dedication to quality.
Advanced Laboratory
Solareast has invested $3 million in an advanced laboratory capable of simulating extreme temperatures from -30°C to 52°C, certified by TUV and Intertek. This lab enables in-depth testing to verify product durability and performance under various conditions. Recent upgrades, including water drawdown and explosion-proof testing areas, underscore our commitment to safety and high-quality standards, ensuring reliable and long-lasting products.
Model | BLN-006TB1 | BLN-010TB1 | BLN-010TB3 | BLN-014TB1 | BLN-014TB3 | BLN-018TB1 | BLN-018TB3 | BLN-024TB3 | ||
Power Supply | V/Ph/Hz | 220~240V/1/50 | 220~240V/1/50 | 380~415/3/50 | 220~240V/1/50 | 380~415/3/50 | 220~240/1/50 | 380~415/3/50 | 380~415/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.50 ~ 8.30 | 4.20-12.20 | 4.20 ~ 12.20 | 5.30 ~ 16.50 | 5.30-16.60 | 6.20-20.50 | 6.20 ~ 20.50 | 6.50-26.10 |
Input Power | A | 2.53 ~ 8.52 | 3.82 ~ 12.77 | 1.46 ~ 4.89 | 5.10 ~ 18.41 | 1.86 ~ 6.70 | 1.36 ~ 5.28 | 1.36 ~ 5.28 | 1.78 ~ 6.45 | |
Current Input | kW | 0.57 ~ 1.92 | 0.86 ~ 2.88 | 0.86 ~ 2.88 | 1.15 ~ 4.15 | 1.15 ~ 4.15 | 6.10 ~ 23.67 | 2.31 ~ 8.96 | 2.87 ~ 10.35 | |
COP | W/W | 4.32 ~ 5.86 | 4.23 ~ 5.39 | 4.23 ~ 5.39 | 3.97 ~ 5.43 | 3.97 ~ 5.43 | 3.88 ~ 5.21 | 3.88 ~ 5.21 | 4.04 ~ 5.43 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.30 ~ 7.62 | 3.85 ~ 11.20 | 3.85 ~ 11.20 | 4.90 ~ 15.10 | 4.90 ~ 15.10 | 6.30 ~ 19.90 | 6.30 ~ 19.90 | 6.90 ~ 26.10 |
Input Power | kW | 0.75 ~ 2.61 | 1.13 ~ 3.75 | 1.13 ~ 3.75 | 1.65 ~ 5.25 | 1.65 ~ 5.25 | 1.65 ~ 6.82 | 1.65 ~ 6.82 | 1.95 ~ 8.55 | |
Current Input | A | 3.32 ~ 11.58 | 5.01 ~ 16.6 | 1.92 ~ 6.37 | 7.32 ~ 23.30 | 1.67 ~ 8.47 | 7.40 ~ 30.56 | 2.80 ~ 11.58 | 3.15 ~ 13.80 | |
COP | W/W | 2.92 ~ 3.33 | 2.99 ~ 3.46 | 2.99 ~ 3.46 | 2.87 ~ 3.38 | 2.87 ~ 3.38 | 2.91 ~ 3.34 | 2.91 ~ 3.34 | 3.05 ~ 3.42 | |
Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 1.80 ~ 7.10 | 2.60 ~ 10.30 | 2.60 ~ 10.30 | 4.50 ~ 13.50 | 4.50 ~ 13.50 | 5.50 ~ 17.50 | 5.50 ~ 17.50 | 5.20 ~ 21.30 |
Power Input | kW | 0.61 ~ 2.43 | 0.91 ~ 3.65 | 0.91 ~ 3.65 | 1.45 ~ 4.85 | 1.45 ~ 4.85 | 1.65 ~ 6.25 | 1.65 ~ 6.25 | 1.95 ~ 8.20 | |
Current Input | A | 2.71 ~ 10.78 | 4.03 ~ 16.19 | 1.55 ~ 6.20 | 6.43 ~ 21.52 | 2.34 ~ 7.82 | 7.40 ~ 28.02 | 2.80 ~ 10.61 | 3.15 ~ 13.23 | |
EER | W/W | 3.04 | 3 | 3 | 2.87 | 2.87 | 2.96 | 2.96 | 2.92 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | ||||||||
ERP Level(Outlet water temp. at 55℃) | / | A++ | ||||||||
Rated Input Power | kW | 2.71 | 3.83 | 3.83 | 6.2 | 6.2 | 7.50 | 7.50 | 10.0 | |
Rated Input Current | A | 12 | 17 | 6.5 | 27.5 | 10.5 | 35.0 | 313.0 | 17.0 | |
Refrigerant Type / Charge / GWP | .../kg | R32/1.25/675 | R32/1.8/675 | R32/1.8/675 | R32/2.8/675 | R32/2.8/675 | R32/3.5/675 | R32/3.5/675 | R32/3.5/675 | |
Rated water flow | m³/h | 1.1 | 1.75 | 1.75 | 2.52 | R32/2.8/675 | 3.20 | 3.20 | 4.12 | |
Fan quantity | / | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | |
Fan motor type | / | DC inverter | ||||||||
Compressor | / | Panasonic / DC inverter / Rotary / EVI | ||||||||
Circulating pump | / | Inverter type / Built-in | ||||||||
IP Class | / | IPX4 | ||||||||
Sound pressure at 1m distance | dB(A) | 49 | 52 | 52 | 53 | 54 | 56 | 55 | 58 | |
Max outlet water temperature | ℃ | 60 | ||||||||
Water piping connections | inch | G1 | G1 | G1 | G1-1/4 | G1-1/4 | G1-1/2 | G1-1/2 | G1-1/2 | |
Pressure drop at rating water flow | kPa | 25 | 27 | 27 | 30 | 30 | 32 | 32 | 35 | |
Operating temperature range (Heating mode) | ℃ | -25~45 | ||||||||
Operating temperature range (Cooing mode) | ℃ | 16~45 | ||||||||
Unpacked Dimensions ( L×D×H ) | mm | 1100*445*850 | 1100*445*850 | 1100*445*850 | 1100*480*850 | 1100*480*850 | 1110*445*1450 | 1110*445*1450 | 1110*445*1450 | |
Packed Dimensions ( L×D×H ) | mm | 1160*530*1010 | 1100*445*850 | 1100*445*850 | 1160*530*1010 | 1160*530*1010 | 1170*530*1610 | 1170*530*1610 | 1170*530*1610 | |
UnPacked Weight | kg | 102 | 107 | 107 | 124 | 124 | 151 | 151 | 160 | |
Packed Weight | kg | 114 | 119 | 119 | 136 | 136 | 168 | 168 | 177 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.
Model | BLN-006TB1 | BLN-010TB1 | BLN-010TB3 | BLN-014TB1 | BLN-014TB3 | BLN-018TB1 | BLN-018TB3 | BLN-024TB3 | ||
Power Supply | V/Ph/Hz | 220~240V/1/50 | 220~240V/1/50 | 380~415/3/50 | 220~240V/1/50 | 380~415/3/50 | 220~240/1/50 | 380~415/3/50 | 380~415/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.50 ~ 8.30 | 4.20-12.20 | 4.20 ~ 12.20 | 5.30 ~ 16.50 | 5.30-16.60 | 6.20-20.50 | 6.20 ~ 20.50 | 6.50-26.10 |
Input Power | A | 2.53 ~ 8.52 | 3.82 ~ 12.77 | 1.46 ~ 4.89 | 5.10 ~ 18.41 | 1.86 ~ 6.70 | 1.36 ~ 5.28 | 1.36 ~ 5.28 | 1.78 ~ 6.45 | |
Current Input | kW | 0.57 ~ 1.92 | 0.86 ~ 2.88 | 0.86 ~ 2.88 | 1.15 ~ 4.15 | 1.15 ~ 4.15 | 6.10 ~ 23.67 | 2.31 ~ 8.96 | 2.87 ~ 10.35 | |
COP | W/W | 4.32 ~ 5.86 | 4.23 ~ 5.39 | 4.23 ~ 5.39 | 3.97 ~ 5.43 | 3.97 ~ 5.43 | 3.88 ~ 5.21 | 3.88 ~ 5.21 | 4.04 ~ 5.43 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.30 ~ 7.62 | 3.85 ~ 11.20 | 3.85 ~ 11.20 | 4.90 ~ 15.10 | 4.90 ~ 15.10 | 6.30 ~ 19.90 | 6.30 ~ 19.90 | 6.90 ~ 26.10 |
Input Power | kW | 0.75 ~ 2.61 | 1.13 ~ 3.75 | 1.13 ~ 3.75 | 1.65 ~ 5.25 | 1.65 ~ 5.25 | 1.65 ~ 6.82 | 1.65 ~ 6.82 | 1.95 ~ 8.55 | |
Current Input | A | 3.32 ~ 11.58 | 5.01 ~ 16.6 | 1.92 ~ 6.37 | 7.32 ~ 23.30 | 1.67 ~ 8.47 | 7.40 ~ 30.56 | 2.80 ~ 11.58 | 3.15 ~ 13.80 | |
COP | W/W | 2.92 ~ 3.33 | 2.99 ~ 3.46 | 2.99 ~ 3.46 | 2.87 ~ 3.38 | 2.87 ~ 3.38 | 2.91 ~ 3.34 | 2.91 ~ 3.34 | 3.05 ~ 3.42 | |
Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 1.80 ~ 7.10 | 2.60 ~ 10.30 | 2.60 ~ 10.30 | 4.50 ~ 13.50 | 4.50 ~ 13.50 | 5.50 ~ 17.50 | 5.50 ~ 17.50 | 5.20 ~ 21.30 |
Power Input | kW | 0.61 ~ 2.43 | 0.91 ~ 3.65 | 0.91 ~ 3.65 | 1.45 ~ 4.85 | 1.45 ~ 4.85 | 1.65 ~ 6.25 | 1.65 ~ 6.25 | 1.95 ~ 8.20 | |
Current Input | A | 2.71 ~ 10.78 | 4.03 ~ 16.19 | 1.55 ~ 6.20 | 6.43 ~ 21.52 | 2.34 ~ 7.82 | 7.40 ~ 28.02 | 2.80 ~ 10.61 | 3.15 ~ 13.23 | |
EER | W/W | 3.04 | 3 | 3 | 2.87 | 2.87 | 2.96 | 2.96 | 2.92 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | ||||||||
ERP Level(Outlet water temp. at 55℃) | / | A++ | ||||||||
Rated Input Power | kW | 2.71 | 3.83 | 3.83 | 6.2 | 6.2 | 7.50 | 7.50 | 10.0 | |
Rated Input Current | A | 12 | 17 | 6.5 | 27.5 | 10.5 | 35.0 | 313.0 | 17.0 | |
Refrigerant Type / Charge / GWP | .../kg | R32/1.25/675 | R32/1.8/675 | R32/1.8/675 | R32/2.8/675 | R32/2.8/675 | R32/3.5/675 | R32/3.5/675 | R32/3.5/675 | |
Rated water flow | m³/h | 1.1 | 1.75 | 1.75 | 2.52 | R32/2.8/675 | 3.20 | 3.20 | 4.12 | |
Fan quantity | / | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | |
Fan motor type | / | DC inverter | ||||||||
Compressor | / | Panasonic / DC inverter / Rotary / EVI | ||||||||
Circulating pump | / | Inverter type / Built-in | ||||||||
IP Class | / | IPX4 | ||||||||
Sound pressure at 1m distance | dB(A) | 49 | 52 | 52 | 53 | 54 | 56 | 55 | 58 | |
Max outlet water temperature | ℃ | 60 | ||||||||
Water piping connections | inch | G1 | G1 | G1 | G1-1/4 | G1-1/4 | G1-1/2 | G1-1/2 | G1-1/2 | |
Pressure drop at rating water flow | kPa | 25 | 27 | 27 | 30 | 30 | 32 | 32 | 35 | |
Operating temperature range (Heating mode) | ℃ | -25~45 | ||||||||
Operating temperature range (Cooing mode) | ℃ | 16~45 | ||||||||
Unpacked Dimensions ( L×D×H ) | mm | 1100*445*850 | 1100*445*850 | 1100*445*850 | 1100*480*850 | 1100*480*850 | 1110*445*1450 | 1110*445*1450 | 1110*445*1450 | |
Packed Dimensions ( L×D×H ) | mm | 1160*530*1010 | 1100*445*850 | 1100*445*850 | 1160*530*1010 | 1160*530*1010 | 1170*530*1610 | 1170*530*1610 | 1170*530*1610 | |
UnPacked Weight | kg | 102 | 107 | 107 | 124 | 124 | 151 | 151 | 160 | |
Packed Weight | kg | 114 | 119 | 119 | 136 | 136 | 168 | 168 | 177 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.