Products

18KW R290 Air Source Heat Pump Efficient heating and cooling solutions for all climate

 
· R290 Refrigerant,low GWP(GWP=3)

· Energy Class A+++
 
· Multi-temperature Zone
 
· SG-READY Function

· Outlet Water Temperature Up To 75℃

· Customizable Heating Curve
 
 
Availability:

Outlet Water Temperature Up To 75℃

  • The R290 Air To Water Heat Pump is designed for heating and cooling, making it compatible with floor heating and cooling, air source floor heating, fan coil units, and radiators.

  • It can heat water up to 75°C, making it ideal for cold climates.

  • When paired with a water tank, it ensures a steady supply of hot water for homes and businesses.

  • This high quality air to water heat pump is designed for long-lasting efficiency.


EVI 9



Multi-Temperature Zone – Easy Control

  • This heating and cooling system allows users to set different temperatures for different rooms.

  • You can adjust heating and hot water settings separately, making it more convenient and energy-efficient.

  • The system automatically adjusts the temperature to save energy and keep indoor conditions comfortable.

  • It is a comfortable air to water heat pump, perfect for customized home heating.

controller 28



Certificates

  • Our high strength air to water heat pump meets strict global standards.


  • Certifications include:
    ✅ CE – Meets European safety and performance requirements.
    ✅ KEYMARK – Recognized certification for heat pump quality.
    ✅ ErP – Ensures energy efficiency.
    ✅ BAFA – Eligible for government subsidies in Germany.
    ✅ MCS – Certified for renewable energy systems.
    ✅ SG Ready – Works with smart energy grids.

    project 15


Quality Assurance

  • Every air to water heat pump for floor heating undergoes multiple quality tests before shipping.


  • Each unit undergoes four essential quality inspections:
    Incoming Materials Inspection – Ensures that only high-quality raw materials are used.
    Helium Inspection – Detects even the smallest leaks for maximum efficiency.
    Halogen Inspection – Ensures no refrigerant leakage, improving reliability.
    Commodity Inspection – Verifies overall product quality before shipment.


  • Before delivery, all units undergo a final halogen test, ensuring only the best-quality and stable air to water heat pump performance for long-term reliability.

    project 2



Laboratory

  • Solareast has a $3 million testing lab for heat pump systems.

  • We test our heat pumps from -30°C to 52°C to ensure they work in all climates.


  • Our labs include:
    Explosion-proof testing – Ensures safety under extreme conditions.
    Water flow testing – Optimizes heat transfer and energy use.


project 14




FAQ

Q1: How much energy does the 18KW R290 Air Source Heat Pump save?

The 18KW R290 Air To Water Heat Pump is built for energy efficiency. It uses less electricity than traditional systems. Thanks to its high COP, it produces more heat with less power, helping users save on energy costs.


Q2: Is the heat pump suitable for extremely cold weather?

Yes! Our high-quality air-to-water heat pump works well in temperatures as low as -30°C. It has defrosting technology to keep it running smoothly in winter.


Q3: How long does installation take, and what is required?

Installation usually takes 1-2 days. A certified HVAC installer will connect the heat pump water heater to your system. If used for hot water, a water tank is recommended.


ModelBLN-006TC1BLN-012TC1BLN-012TC3BLN-018TC1BLN-018TC3
Power SupplyV/Ph/Hz220~240/1/50380~415V/3/50380~415V/3/50220~240/1/50380~415V/3/50
Nominal Heating (Max)      (A7/6℃,W30/35℃)Heating Capacity kW2.92 ~ 9.104.30 ~ 15.204.30 ~ 15.207.24 ~ 21.907.24 ~ 21.90
Power InputkW0.61 ~ 2.110.87 ~ 3.730.87 ~ 3.731.50 ~ 5.881.50 ~ 5.88
Current InputA2.80 ~ 9.254.02 ~ 16.381.78 ~ 6.046.86 ~ 30.252.82 ~ 9.16
COPW/W4.31 ~ 5.664.07 ~ 5.574.07 ~ 5.573.82 ~ 5.593.82 ~ 5.59
Nominal Heating (Max)    (A7/6℃,W47/55℃)Heating Capacity kW2.99 ~ 8.164.25 ~ 14.554.25 ~ 14.556.36 ~ 19.456.36 ~ 19.45
Power InputkW1.03 ~ 2.921.45 ~ 4.281.45 ~ 4.282.15 ~ 6.852.15 ~ 6.85
Current InputA4.57 ~ 12.796.71 ~ 18.802.84 ~ 6.789.84 ~ 30.129.84 ~ 30.12
COPW/W2.79 ~ 3.462.83 ~ 3.452.83 ~ 3.452.84 ~ 3.572.84 ~ 3.57
Nominal Heating (Max)    (A357/24℃,W12/7℃)Heating Capacity kW1.38 ~ 5.703.65 ~ 11.043.65 ~ 11.044.55 ~ 17.204.55 ~ 17.20
Power InputkW0.67 ~ 2.441.12~3.971.12 ~ 3.971.85 ~ 7.311.85 ~ 7.31
Current InputA3.06 ~ 10.275.18~17.441.97 ~ 6.308.47 ~ 32.12.99 ~ 11.26
ERP Level(Outlet water temp. at 35℃)/
A+++
Rated Input PowerkW3.55.855.857.510.5
Rated Input Current A1525103517
Refrigerant Type / Charge / GWP... / kgR290 / 0.55 / 3R290 / 1.05 / 3R290 / 1.4 / 3
Rated water flowm³/h11.4
2.063.1
Fan quantity/1
Fan motor type/DC inverter
Compressor/DC inverter
Circulating pump/Inverter type / Built ~ in
IP Class/IPX4
Sound pressure at 1m distancedB(A)4653545656
Max. outlet water Temp.°C75
Water Piping ConnectionsinchG1G1 ~ 1 / 4G1 ~ 1 / 4
Water Pressure DropkPa2050
Operating temperature range (Heating mode)°C ~ 25~45
Operating temperature range (Cooing mode)°C16~45
Unpacked Dimensions ( L×D×H )mm1187*418*8051287*448*9041287*448*9041187*488*14561187*488*1456
Packed Dimensions  ( L×D×H )mm1217*463*9201317*493*10201317*493*10201217*538*15701217*538*1570
UnPacked Weightkg110134134195195
Packed Weightkg122146146208208

* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.

Previous: 
Next: 

Contact Information

Add: NO.73 Defu Rd. Xingtan Town, Shunde District, Foshan City, Guangdong Province,P.R. of China
E-mail: heatpump@solareast.com
Contact Us
Copyright © 2023 Solareast Heat Pump Ltd. All Rights Reserved. Sitemap | Privacy Policy