Availability: | |
---|---|
The R290 Air To Water Heat Pump is designed for heating and cooling, making it compatible with floor heating and cooling, air source floor heating, fan coil units, and radiators.
It can heat water up to 75°C, making it ideal for cold climates.
When paired with a water tank, it ensures a steady supply of hot water for homes and businesses.
This high quality air to water heat pump is designed for long-lasting efficiency.
This heating and cooling system allows users to set different temperatures for different rooms.
You can adjust heating and hot water settings separately, making it more convenient and energy-efficient.
The system automatically adjusts the temperature to save energy and keep indoor conditions comfortable.
It is a comfortable air to water heat pump, perfect for customized home heating.
Our high strength air to water heat pump meets strict global standards.
Certifications include:
✅ CE – Meets European safety and performance requirements.
✅ KEYMARK – Recognized certification for heat pump quality.
✅ ErP – Ensures energy efficiency.
✅ BAFA – Eligible for government subsidies in Germany.
✅ MCS – Certified for renewable energy systems.
✅ SG Ready – Works with smart energy grids.
Every air to water heat pump for floor heating undergoes multiple quality tests before shipping.
Each unit undergoes four essential quality inspections:
✅ Incoming Materials Inspection – Ensures that only high-quality raw materials are used.
✅ Helium Inspection – Detects even the smallest leaks for maximum efficiency.
✅ Halogen Inspection – Ensures no refrigerant leakage, improving reliability.
✅ Commodity Inspection – Verifies overall product quality before shipment.
Before delivery, all units undergo a final halogen test, ensuring only the best-quality and stable air to water heat pump performance for long-term reliability.
Solareast has a $3 million testing lab for heat pump systems.
We test our heat pumps from -30°C to 52°C to ensure they work in all climates.
Our labs include:
✅ Explosion-proof testing – Ensures safety under extreme conditions.
✅ Water flow testing – Optimizes heat transfer and energy use.
Q1: How much energy does the 18KW R290 Air Source Heat Pump save?
The 18KW R290 Air To Water Heat Pump is built for energy efficiency. It uses less electricity than traditional systems. Thanks to its high COP, it produces more heat with less power, helping users save on energy costs.
Q2: Is the heat pump suitable for extremely cold weather?
Yes! Our high-quality air-to-water heat pump works well in temperatures as low as -30°C. It has defrosting technology to keep it running smoothly in winter.
Q3: How long does installation take, and what is required?
Installation usually takes 1-2 days. A certified HVAC installer will connect the heat pump water heater to your system. If used for hot water, a water tank is recommended.
The R290 Air To Water Heat Pump is designed for heating and cooling, making it compatible with floor heating and cooling, air source floor heating, fan coil units, and radiators.
It can heat water up to 75°C, making it ideal for cold climates.
When paired with a water tank, it ensures a steady supply of hot water for homes and businesses.
This high quality air to water heat pump is designed for long-lasting efficiency.
This heating and cooling system allows users to set different temperatures for different rooms.
You can adjust heating and hot water settings separately, making it more convenient and energy-efficient.
The system automatically adjusts the temperature to save energy and keep indoor conditions comfortable.
It is a comfortable air to water heat pump, perfect for customized home heating.
Our high strength air to water heat pump meets strict global standards.
Certifications include:
✅ CE – Meets European safety and performance requirements.
✅ KEYMARK – Recognized certification for heat pump quality.
✅ ErP – Ensures energy efficiency.
✅ BAFA – Eligible for government subsidies in Germany.
✅ MCS – Certified for renewable energy systems.
✅ SG Ready – Works with smart energy grids.
Every air to water heat pump for floor heating undergoes multiple quality tests before shipping.
Each unit undergoes four essential quality inspections:
✅ Incoming Materials Inspection – Ensures that only high-quality raw materials are used.
✅ Helium Inspection – Detects even the smallest leaks for maximum efficiency.
✅ Halogen Inspection – Ensures no refrigerant leakage, improving reliability.
✅ Commodity Inspection – Verifies overall product quality before shipment.
Before delivery, all units undergo a final halogen test, ensuring only the best-quality and stable air to water heat pump performance for long-term reliability.
Solareast has a $3 million testing lab for heat pump systems.
We test our heat pumps from -30°C to 52°C to ensure they work in all climates.
Our labs include:
✅ Explosion-proof testing – Ensures safety under extreme conditions.
✅ Water flow testing – Optimizes heat transfer and energy use.
Q1: How much energy does the 18KW R290 Air Source Heat Pump save?
The 18KW R290 Air To Water Heat Pump is built for energy efficiency. It uses less electricity than traditional systems. Thanks to its high COP, it produces more heat with less power, helping users save on energy costs.
Q2: Is the heat pump suitable for extremely cold weather?
Yes! Our high-quality air-to-water heat pump works well in temperatures as low as -30°C. It has defrosting technology to keep it running smoothly in winter.
Q3: How long does installation take, and what is required?
Installation usually takes 1-2 days. A certified HVAC installer will connect the heat pump water heater to your system. If used for hot water, a water tank is recommended.
Model | BLN-006TC1 | BLN-012TC1 | BLN-012TC3 | BLN-018TC1 | BLN-018TC3 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 380~415V/3/50 | 380~415V/3/50 | 220~240/1/50 | 380~415V/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.30 ~ 15.20 | 4.30 ~ 15.20 | 7.24 ~ 21.90 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.87 ~ 3.73 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 4.02 ~ 16.38 | 1.78 ~ 6.04 | 6.86 ~ 30.25 | 2.82 ~ 9.16 | |
COP | W/W | 4.31 ~ 5.66 | 4.07 ~ 5.57 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 4.25 ~ 14.55 | 4.25 ~ 14.55 | 6.36 ~ 19.45 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.45 ~ 4.28 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 6.71 ~ 18.80 | 2.84 ~ 6.78 | 9.84 ~ 30.12 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.83 ~ 3.45 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | 2.84 ~ 3.57 | |
Nominal Heating (Max) (A357/24℃,W12/7℃) | Heating Capacity | kW | 1.38 ~ 5.70 | 3.65 ~ 11.04 | 3.65 ~ 11.04 | 4.55 ~ 17.20 | 4.55 ~ 17.20 |
Power Input | kW | 0.67 ~ 2.44 | 1.12~3.97 | 1.12 ~ 3.97 | 1.85 ~ 7.31 | 1.85 ~ 7.31 | |
Current Input | A | 3.06 ~ 10.27 | 5.18~17.44 | 1.97 ~ 6.30 | 8.47 ~ 32.1 | 2.99 ~ 11.26 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||||
Rated Input Power | kW | 3.5 | 5.85 | 5.85 | 7.5 | 10.5 | |
Rated Input Current | A | 15 | 25 | 10 | 35 | 17 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.05 / 3 | R290 / 1.4 / 3 | |||
Rated water flow | m³/h | 1 | 1.4 | 2.06 | 3.1 | ||
Fan quantity | / | 1 | |||||
Fan motor type | / | DC inverter | |||||
Compressor | / | DC inverter | |||||
Circulating pump | / | Inverter type / Built ~ in | |||||
IP Class | / | IPX4 | |||||
Sound pressure at 1m distance | dB(A) | 46 | 53 | 54 | 56 | 56 | |
Max. outlet water Temp. | °C | 75 | |||||
Water Piping Connections | inch | G1 | G1 ~ 1 / 4 | G1 ~ 1 / 4 | |||
Water Pressure Drop | kPa | 20 | 50 | ||||
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||||
Operating temperature range (Cooing mode) | °C | 16~45 | |||||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1287*448*904 | 1187*488*1456 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1317*493*1020 | 1217*538*1570 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 134 | 195 | 195 | |
Packed Weight | kg | 122 | 146 | 146 | 208 | 208 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.
Model | BLN-006TC1 | BLN-012TC1 | BLN-012TC3 | BLN-018TC1 | BLN-018TC3 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 380~415V/3/50 | 380~415V/3/50 | 220~240/1/50 | 380~415V/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92 ~ 9.10 | 4.30 ~ 15.20 | 4.30 ~ 15.20 | 7.24 ~ 21.90 | 7.24 ~ 21.90 |
Power Input | kW | 0.61 ~ 2.11 | 0.87 ~ 3.73 | 0.87 ~ 3.73 | 1.50 ~ 5.88 | 1.50 ~ 5.88 | |
Current Input | A | 2.80 ~ 9.25 | 4.02 ~ 16.38 | 1.78 ~ 6.04 | 6.86 ~ 30.25 | 2.82 ~ 9.16 | |
COP | W/W | 4.31 ~ 5.66 | 4.07 ~ 5.57 | 4.07 ~ 5.57 | 3.82 ~ 5.59 | 3.82 ~ 5.59 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99 ~ 8.16 | 4.25 ~ 14.55 | 4.25 ~ 14.55 | 6.36 ~ 19.45 | 6.36 ~ 19.45 |
Power Input | kW | 1.03 ~ 2.92 | 1.45 ~ 4.28 | 1.45 ~ 4.28 | 2.15 ~ 6.85 | 2.15 ~ 6.85 | |
Current Input | A | 4.57 ~ 12.79 | 6.71 ~ 18.80 | 2.84 ~ 6.78 | 9.84 ~ 30.12 | 9.84 ~ 30.12 | |
COP | W/W | 2.79 ~ 3.46 | 2.83 ~ 3.45 | 2.83 ~ 3.45 | 2.84 ~ 3.57 | 2.84 ~ 3.57 | |
Nominal Heating (Max) (A357/24℃,W12/7℃) | Heating Capacity | kW | 1.38 ~ 5.70 | 3.65 ~ 11.04 | 3.65 ~ 11.04 | 4.55 ~ 17.20 | 4.55 ~ 17.20 |
Power Input | kW | 0.67 ~ 2.44 | 1.12~3.97 | 1.12 ~ 3.97 | 1.85 ~ 7.31 | 1.85 ~ 7.31 | |
Current Input | A | 3.06 ~ 10.27 | 5.18~17.44 | 1.97 ~ 6.30 | 8.47 ~ 32.1 | 2.99 ~ 11.26 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |||||
Rated Input Power | kW | 3.5 | 5.85 | 5.85 | 7.5 | 10.5 | |
Rated Input Current | A | 15 | 25 | 10 | 35 | 17 | |
Refrigerant Type / Charge / GWP | ... / kg | R290 / 0.55 / 3 | R290 / 1.05 / 3 | R290 / 1.4 / 3 | |||
Rated water flow | m³/h | 1 | 1.4 | 2.06 | 3.1 | ||
Fan quantity | / | 1 | |||||
Fan motor type | / | DC inverter | |||||
Compressor | / | DC inverter | |||||
Circulating pump | / | Inverter type / Built ~ in | |||||
IP Class | / | IPX4 | |||||
Sound pressure at 1m distance | dB(A) | 46 | 53 | 54 | 56 | 56 | |
Max. outlet water Temp. | °C | 75 | |||||
Water Piping Connections | inch | G1 | G1 ~ 1 / 4 | G1 ~ 1 / 4 | |||
Water Pressure Drop | kPa | 20 | 50 | ||||
Operating temperature range (Heating mode) | °C | ~ 25~45 | |||||
Operating temperature range (Cooing mode) | °C | 16~45 | |||||
Unpacked Dimensions ( L×D×H ) | mm | 1187*418*805 | 1287*448*904 | 1287*448*904 | 1187*488*1456 | 1187*488*1456 | |
Packed Dimensions ( L×D×H ) | mm | 1217*463*920 | 1317*493*1020 | 1317*493*1020 | 1217*538*1570 | 1217*538*1570 | |
UnPacked Weight | kg | 110 | 134 | 134 | 195 | 195 | |
Packed Weight | kg | 122 | 146 | 146 | 208 | 208 |
* Please refer to the nameplate for product upgrades or changes in specifications without prior notice.