6kW/8kW/10kW/12kW16kW A+++ 30dB(A) Monobloc Heat Pump for Heating Cooling And DHW - Ultra Series

· Energy Class: A+++

· High Efficiency

· Microbubble Valve Technology

· Refrigerant Leak Detection Function

· Water Pressure Sensing Function

· Water Flow Sensing Function

· Low Noise Sound Power Level as Low as 32.9 dB(A)

· Outlet Water Temperature Up To 80℃
Availability:


A+++ Energy Efficiency

A+++ Monobloc Heat Pump has achieved the EU's highest energy efficiency rating of A+++, delivering top-tier energy savings during 55°C hot water output. It efficiently extracts heat from the air in low-temperature winter conditions, significantly reducing energy consumption for heating or domestic hot water compared to traditional electric heating systems. Suitable for whole-house coverage, it provides constant, comfortable hot water to meet multiple household water demands. With low operating costs and zero emissions, this single unit integrates heating, cooling, and domestic hot water functions into one efficient, eco-friendly, and comfortable heating solution.


High efficiency A+++


Low Noise at 32.9 dB(A)

Low noise Monobloc Heat Pump  runs at a quiet 32.9 decibels, well below industry standards. It's almost as quiet as a library. This low noise comes from advanced acoustic engineering, allowing near-silent operation in heating, cooling, and hot water modes. Users can run it all day in bedrooms, living rooms, and other spaces without worrying about noise. It keeps your home peaceful and comfortable. This quiet performance highlights the unit's premium quality and offers a top-notch solution for anyone wanting a calm living space.


冷暖机详情图-低噪音-U系列




Intelligent Flow Regulation for Optimised Energy Efficiency

The heat pump uses advanced flow sensors to monitor the flow rate and speed of circulating and domestic water. It automatically adjusts the pump speed for even heating and cooling. This prevents dry-running and blockages while optimizing energy efficiency. It also alerts users to pipeline issues, improving the use of water and electricity. This helps conserve energy and reduce emissions.


U系列核心配件-1



Micro-bubble Self-cleaning Enhances Thermal Efficiency


The Monobloc Heat Pump for heating, cooling and DHW has a precision micro-bubble valve. This valve injects tiny micro-bubbles into the circulating water. This technology boosts heat exchange efficiency. It does this by enhancing heat transfer through bubble implosion. At the same time, it cleans pipes and heat exchangers. This helps prevent scale buildup. As a result, it provides cleaner hot water, even heating, and a longer equipment lifespan. It also meets European high-efficiency energy standards.


U系列核心配件-2



Refrigerant monitoring, safety and compliance

This heat pump features a real-time refrigerant leak detection sensor. It constantly checks refrigerant levels in the system. If it detects abnormal levels, the system shuts down and sounds an alarm. This prevents the release of harmful gases and protects both user health and the environment. This design meets EU REACH Regulation and F-Gas requirements, effectively reducing explosion risks.


U系列核心配件-3


Dynamic hydraulic pressure balancing, stable output

The heat pump has a water pressure sensor that monitors changes in water pressure. This design allows for better control of heating and hot water pressure. It helps prevent pipe bursts from high pressure and unstable heating from low pressure. This ensures a steady water supply all day and efficient heat exchange. As a result, it maintains a consistent hot water temperature. This heat pump meets strict reliability and stability standards from the European Energy Performance of Buildings Directive (EPBD),ensuring a sustainable heating and cooling heat pump performance.


U系列核心配件-4


Solareast Advanced Manufacturing Facilities

Solareast leverages cutting-edge automation in its production processes, including advanced laser cutting, powder coating, high-pressure foaming, and precision assembly technologies. These automated systems ensure consistent product quality, improved production efficiency, and adherence to rigorous international standards. This focus on technological innovation guarantees that every heat pump meets exacting specifications for reliability, durability, and performance.


Heat Pump Factory Diagram




FAQ

Q1: How does the refrigerant leak sensor on this heat pump operate?

The refrigerant leak sensor employs a dual-light source, dual-channel design to monitor refrigerant concentration changes within the system in real time. Upon detecting abnormal levels, the system automatically triggers shutdown and emits an audible and visual alarm, thereby preventing harmful gas release, explosion risks, and environmental pollution. This design enhances the safety and stability of heat pump operation, providing reliable assurance for domestic heating, cooling, and domestic hot water supply.


Q2: What is Micro-bubble Valve technology?

This heat pump incorporates microbubble valve technology, which achieves efficient heat exchange and automatic cleaning by introducing minute air bubbles into the circulating water. Specifically, the microbubbles rupture during heat exchange, releasing energy to enhance thermal conductivity while simultaneously flushing the surfaces of pipes and heat exchangers to prevent scale accumulation.


Q3: Is the noise level of this heat pump really only 32.9 decibels?

Certainly. This heat pump product employs noise-reduction technology that couples the compressor and fan. Utilising advanced noise-reduction techniques, including hexagonal floating chambers combined with a two-stage vibration-isolation design, multi-layer composite high-efficiency sound-absorbing materials, and a thickened structure with a metal compressor sound-dampening chamber, it achieves comprehensive vibration dampening, sound absorption, and sound insulation. This ensures quiet and reliable operation.











Model

Unit

BLN-006TD1

BLN-008TD1

BLN-010TD1

BLN-012TD1

BLN-014TD1

BLN-016TD1

BLN-008TD3

BLN-010TD3

BLN-012TD3

BLN-014TD3

BLN-016TD3

Power supply

V/Ph/Hz

220-240/1/50

380-415/3/50

Heating A7W35



Rated Heating Capacity

kW

6.00

8.00

10.00

12.10

14.00

16.00

8.00

10.00

12.10

14.00

16.00

Rated Power Input

kW

1.18

1.48

1.96

2.51

2.89

3.40

1.51

1.99

2.54

2.92

3.44

COP

w/w

5.10

5.39

5.10

4.82

4.85

4.70

5.30

5.03

4.77

4.80

4.65

Heating A7W55



Rated Heating Capacity

kW

6.00

8.00

10.00

12.10

14.00

16.00

8.00

10.00

12.10

14.00

16.00

Rated Power Input

kW

1.88

2.37

3.05

3.92

4.44

5.25

2.42

3.09

3.89

4.52

5.33

COP

w/w

3.20

3.38

3.28

3.09

3.15

3.05

3.30

3.24

3.11

3.10

3.00

Cooling A35W7



Rated Cooling Capacity

kW

6.00

8.00

10.00

12.00

12.50

14.00

8.00

10.00

12.00

12.50

14.00

Rated Power Input

kW

1.90

2.48

3.15

3.96

4.10

4.91

2.42

3.15

3.97

4.17

5.00

EER

w/w

3.16

3.23

3.17

3.03

3.05

2.85

3.3

3.17

3.02

3.00

2.80

Cooling A35W18



Rated Cooling Capacity

kW

6.00

8.00

10.00

12.00

14.00

15.00

8.00

10.00

12.00

14.00

15.00

Rated Power Input

kW

1.24

1.57

2.02

2.60

3.15

3.49

1.56

2.01

2.60

3.18

3.53

EER

w/w

4.83

5.11

4.94

4.62

4.45

4.30

5.13

4.98

4.61

4.40

4.25

SCOP






Average climate, W35°C



kWh/kWh

5.47

5.54

5.50

5.36

4.95

4.90

5.34

5.21

5.22

4.90

4.85

%

216

219

217

211

195

193

211

205

206

193

191

/

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

Average climate, W55°C



kWh/kWh

3.96

4.06

4.09

4.02

3.89

3.87

3.95

3.94

3.93

3.87

3.84

%

155

159

161

158

153

152

155

155

154

152

151

/

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

A+++

Operating temperature range (heating mode)

Ambient temperature range

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

-25~35

Water outlet temperature range

20~80

20~80

20~80

20~80

20~80

20~80

20~80

20~80

20~80

20~80

20~80

Operating temperature range (cooling mode)

Ambient temperature range

15~45

15~45

15~45

15~45

15~45

15~45

15~45

15~45

15~45

15~45

15~45

Water outlet temperature range

5~25

5~25

5~25

5~25

5~25

5~25

5~25

5~25

5~25

5~25

5~25

Operating temperature range (hot water)

Ambient temperature range

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

-25~45

Water outlet temperature range

20~70

20~70

20~70

20~70

20~70

20~70

20~70

20~70

20~70

20~70

20~70

ErP sound power level


Average climate, W35°C

dB(A)

44

49

49

50

53

55

49

49

50

53

55

Average climate, W55°C

dB(A)

46

49

49

50

54

56

49

49

50

54

56

Sound pressure (3m)


Average climate, W35°C

dB(A)

30

35

35

36

39

41

35

35

36

39

41

Average climate, W55°C

dB(A)

33

35

35

36

40

42

35

35

36

40

42

Max. input power

kW

3.1

6.1

6.1

6.1

7.5

8.5

6.5

6.5

6.5

9

10.4

Max. input current

A

15.9

30

30

30

33

37

12

12

12

13.5

14.5

Refrigerant

TYPE/(GWP)

/

R290(3)

Charged volume

kg

0.65

1.20

1.20

1.20

1.60

1.60

1.20

1.20

1.20

1.60

1.60

Water side connection

Inch

G1

Water Pressure Drop

kPa

10

10

15

20

20

25

10

15

20

20

25

Min/Max Water Pressure

MPa

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

0.1/0.3

Rated Water Flow

m³/h

1.05

1.38

1.72

2.06

2.40

2.75

1.38

1.72

2.06

2.40

2.75

Net Dimensions ( L×W×H )

mm

1300×548×912

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

1470×578×1070

Packing dimensions

 ( L×W×H )

mm

1335*590*1052

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

1505×615×1210

Net Weight

kg

150

197

197

197

213

213

204

204

204

221

221

Gross weight

kg

165

212

212

212

228

228

219

219

219

236

236

Note: Parameters are subject to change without prior notice. Please refer to the unit nameplate.




Previous: 
Next: 

Contact Information

Add: NO.73 Defu Rd. Xingtan Town, Shunde District, Foshan City, Guangdong Province,P.R. of China
E-mail: heatpump@solareast.com
Contact Us
Copyright © 2023 Solareast Heat Pump Ltd. All Rights Reserved. Sitemap | Privacy Policy