Availability: | |
---|---|
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=Y9Y2rir3sJU
R32 Refrigerant: An Eco-friendly Choice
Equipped with eco-friendly R32 refrigerant, Solareast's BLN series heat pumps effectively reduce greenhouse gas emissions and support sustainability. With a lower global warming potential, R32 aligns with Solareast’s commitment to green technology, providing efficient and environmentally responsible home heating solutions.
Outlet Water Temperature Up To 60°C
The Solareast BLN series heat pumps deliver high outlet water temperatures of up to 60°C, ensuring reliable hot water access for households. This efficient heating capability guarantees comfort even in colder climates, making it ideal for high-demand applications such as warm baths and showers.
Ultra Quiet Operation
Solareast BLN heat pumps are designed to operate at ultra-quiet levels, as low as 45 dB, providing a peaceful heating experience for homes. Featuring advanced noise-reduction technology, these units deliver optimal efficiency and comfort without disturbing your living environment, making them perfect for quiet residential settings.
Automated Manufacturing Process
Solareast incorporates advanced automation technologies in its manufacturing process to enhance production efficiency and product quality. Utilizing precision laser cutting, high-pressure foaming, durable powder coating, and accurate bending techniques, the company ensures that each heat pump meets stringent quality control standards. This automation not only improves production consistency but also helps meet the growing market demand, ensuring timely delivery of high-quality products.
Advanced Laboratory
With a $3 million investment, Solareast's cutting-edge laboratory is certified by TUV and Intertek, enabling comprehensive testing under extreme temperatures ranging from -30ºC to 52ºC. The lab conducts various evaluations, including water drawdown tests and explosion-proof assessments, to guarantee the reliability and efficiency of the heat pumps in challenging conditions.
To learn more about Solareast Heat Pumps, click the link to watch the video! ➡https://www.youtube.com/watch?v=Y9Y2rir3sJU
R32 Refrigerant: An Eco-friendly Choice
Equipped with eco-friendly R32 refrigerant, Solareast's BLN series heat pumps effectively reduce greenhouse gas emissions and support sustainability. With a lower global warming potential, R32 aligns with Solareast’s commitment to green technology, providing efficient and environmentally responsible home heating solutions.
Outlet Water Temperature Up To 60°C
The Solareast BLN series heat pumps deliver high outlet water temperatures of up to 60°C, ensuring reliable hot water access for households. This efficient heating capability guarantees comfort even in colder climates, making it ideal for high-demand applications such as warm baths and showers.
Ultra Quiet Operation
Solareast BLN heat pumps are designed to operate at ultra-quiet levels, as low as 45 dB, providing a peaceful heating experience for homes. Featuring advanced noise-reduction technology, these units deliver optimal efficiency and comfort without disturbing your living environment, making them perfect for quiet residential settings.
Automated Manufacturing Process
Solareast incorporates advanced automation technologies in its manufacturing process to enhance production efficiency and product quality. Utilizing precision laser cutting, high-pressure foaming, durable powder coating, and accurate bending techniques, the company ensures that each heat pump meets stringent quality control standards. This automation not only improves production consistency but also helps meet the growing market demand, ensuring timely delivery of high-quality products.
Advanced Laboratory
With a $3 million investment, Solareast's cutting-edge laboratory is certified by TUV and Intertek, enabling comprehensive testing under extreme temperatures ranging from -30ºC to 52ºC. The lab conducts various evaluations, including water drawdown tests and explosion-proof assessments, to guarantee the reliability and efficiency of the heat pumps in challenging conditions.
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |
Model | BLN-009TA1 | BLN-012TA1 | BLN-015TA1 | BLN-018TA1 | BLN-012TA3 | BLN-015TA3 | BLN-018TA3 | BLN-026TA3 | BLN-032TA3 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 30℃ / 35℃ | |||||||||||
Heating | Capacity | kW | 3.4 ~ 10.2 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 4.6 ~ 12.8 | 5.2 ~ 16.8 | 6.8 ~ 20.5 | 11.8 ~ 28.6 | 14.5 ~ 36.3 |
Rated input | kW | 0.7 ~ 3.2 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.0 ~ 5.1 | 0.8 ~ 3.9 | 1.0 ~ 5.1 | 1.5 ~ 5.9 | 2.9 ~ 6.2 | 3.8 ~ 7.6 | |
SCOP | 4.29 | 4.31 | 4.26 | 4.21 | 4.31 | 4.26 | 4.21 | 4.36 | 4.20 | ||
Performance Condition: Outdoor air 7℃ / 6℃, Inlet / Outlet water 50℃ / 55℃ | |||||||||||
Heating | Capacity | kW | 3.6 ~ 10.3 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 4.7 ~ 12.9 | 5.3 ~ 16.8 | 6.9 ~ 20.8 | 11.8 ~ 28.8 | 14.7 ~ 36.6 |
Rated input | kW | 0.9 ~ 4.3 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 1.4 ~ 5.1 | 1.3 ~ 6.7 | 2.0 ~ 7.7 | 3.8 ~ 8.1 | 4.9 ~ 9.9 | |
SCOP | 3.36 | 3.30 | 3.32 | 3.65 | 3.30 | 3.32 | 3.65 | 3.69 | 3.52 | ||
Performance Condition: Outdoor air 35℃ / 24℃, Inlet / Outlet water 12℃ / 7℃ | |||||||||||
Cooling | Capacity | kW | 2.1-8.2 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 2.6 ~ 9.1 | 3.6 ~ 11.5 | 4.2 ~ 16.8 | 5.2 ~ 19.5 | 6.2 ~24.5 |
Rated input | kW | 1.4 ~ 4.5 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 1.9 ~ 4.7 | 2.0 ~ 7.8 | 2.8 ~8.9 | 4.8 ~ 9.3 | 5.1 ~ 11.4 | |
EER | 2.82 | 2.77 | 2.86 | 2.98 | 2.77 | 2.86 | 2.98 | 2.83 | 2.96 | ||
Energy class (SCOP) | Outlet water temp. at 35C | A++ | |||||||||
Outlet water temp. at 55C | A++ | ||||||||||
Refrigerant | Type | R32 | |||||||||
Charged volume | kg | 1.5 | 1.6 | 3.2 | 3.2 | 1.6 | 3.2 | 3.2 | 5.0 | 6.8 | |
Noise level | Heating | dB(A) | 45 | 45 | 48 | 48 | 45 | 48 | 48 | 50 | 50 |
Cooling | dB(A) | 46 | 46 | 49 | 49 | 46 | 49 | 49 | 51 | 51 | |
Water flow volume | m³/h | 1.55 | 2.05 | 2.55 | 3.10 | 2.05 | 2.55 | 3.10 | 4.50 | 5.50 | |
Water piping connections | mm | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN25 Male | DN32 Male | DN32 Male | DN32 Male | |
Operating temperature range | Cooling | ℃ | 16 - 48 | ||||||||
Heating | ℃ | -25 - 48 | |||||||||
DHW | ℃ | -25 - 48 | |||||||||
Net dimensions (W*D*H) | mm | 1005*375*800 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1005*375*800 | 1025*380*1320 | 1077*377*1460 | 1127*427*1560 | 1127*427*1560 | |
Packed dimensions (W*D*H) | mm | 1080*455*960 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1080*455*960 | 1076*440*1460 | 1150*450*1620 | 1150*500*1720 | 1150*500*1720 | |
Net/Gross weight | kg | 70/80 | 70585 | 124/140 | 147/165 | 75/85 | 124/140 | 147/165 | 160/178 | 200/218 |